fbpx

DE165 GC Generator Set (60 Hz) 16844

DE165 GC Generator Set (60 Hz)
16844 DE165 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
150 ekW
Minimum Rating
150 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
150 ekW
Minimum Rating
150 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4043lb

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
    • Low fuel level shutdown
  • Genset Control
    • Battery charger
    • Volt free contacts for common alarm
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Earth leakage
    • USB to RS485 Communications device
    • Earth fault
    • Emergency stop with key
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Fuel Systems
    • High fuel level alarm
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 400A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
150 ekW
Minimum Rating
150 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4043lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
    • Low fuel level shutdown
  • Genset Control
    • Battery charger
    • Volt free contacts for common alarm
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Earth leakage
    • USB to RS485 Communications device
    • Earth fault
    • Emergency stop with key
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Fuel Systems
    • High fuel level alarm
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 400A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF