Maximum Rating
175 ekW
Minimum Rating
175 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
175 ekW
Minimum Rating
175 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4257lb

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Genset Control
    • Battery charger
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Low coolant level shutdown
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A

Specifications

Generator Set Specifications

Maximum Rating
175 ekW
Minimum Rating
175 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4257lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Genset Control
    • Battery charger
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Low coolant level shutdown
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A