Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
- Standby Rating
- 2500 kVA
- Prime Power Rating
- 2275 kVA
- Emissions/Fuel Strategy
- Low Fuel, Low Emissions
- Voltage
- 380 to 11000 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Maximum Rating
- 2500 kVA
- Minimum Rating
- 2000 kVA
Engine Specifications
- Engine Model
- 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69in
- Stroke
- 8.46in
- Displacement
- 4764.73in
- Compression Ratio
- 15.5:1
- Aspiration
- TA
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™3
Generator Set Dimensions
- Length - Minimum
- 233.4in
- Length - Maximum
- 251.7in
- Width - Maximum
- 90in
- Height - Maximum
- 93.2in
- Dry Weight - Genset (minimum)
- 31900lb
- Dry Weight - Genset (maximum)
- 40320lb
Standard Equipment:
- Air Inlet
- Air cleaner
- Cooling
- Package mounted radiator
- Exhaust
- Exhaust flange outlet
- Fuel
- Secondary fuel filters
- Fuel priming pump
- Primary fuel filter with integral water separator
- Generator
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
- Power Termination
- Busbar
- Control Panel
- Cat ECS 100
- General
- Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment:
- Exhaust
- Exhaust mufflers (except Tier 4)
- Generator
- Permanent magnet excitation (PMG)
- Internal excitation (IE)
- Anti-condensation heater
- Oversize and premium generators
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Control Panels
- Generator temperature monitoring & protection
- Digital I/O module
- Load share module
- EMCP 4.4
- Remote monitoring software
- Mounting
- Spring type vibration isolators
- IBC isolators
- Rubber anti-vibration mounts
- Starting/charging
- Oversize batteries
- Charging alternator
- Heavy duty starting system
- Jacket water heater
- Air starting motor with control and silencer
- Battery chargers
- General
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EU Certificate of Conformance (CE)
- The following options are based on regional and product configuration:
- Enclosures: Sound attenuated, weather protective
- Automatic transfer switches (ATS)
- UL 2200 package
- Integral & sub-base UL listed dual wall fuel tanks
- Integral & sub-base fuel tanks
- EEC Declaration of Conformity
- CSA Certification
Specifications
Generator Set Specifications
- Standby Rating
- 2500 kVA
- Prime Power Rating
- 2275 kVA
- Emissions/Fuel Strategy
- Low Fuel, Low Emissions
- Voltage
- 380 to 11000 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Maximum Rating
- 2500 kVA
- Minimum Rating
- 2000 kVA
Engine Specifications
- Engine Model
- 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69in
- Stroke
- 8.46in
- Displacement
- 4764.73in
- Compression Ratio
- 15.5:1
- Aspiration
- TA
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™3
Generator Set Dimensions
- Length - Minimum
- 233.4in
- Length - Maximum
- 251.7in
- Width - Maximum
- 90in
- Height - Maximum
- 93.2in
- Dry Weight - Genset (minimum)
- 31900lb
- Dry Weight - Genset (maximum)
- 40320lb
Standard/Optional Features
Standard Equipment:
- Air Inlet
- Air cleaner
- Cooling
- Package mounted radiator
- Exhaust
- Exhaust flange outlet
- Fuel
- Secondary fuel filters
- Fuel priming pump
- Primary fuel filter with integral water separator
- Generator
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
- Power Termination
- Busbar
- Control Panel
- Cat ECS 100
- General
- Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment:
- Exhaust
- Exhaust mufflers (except Tier 4)
- Generator
- Permanent magnet excitation (PMG)
- Internal excitation (IE)
- Anti-condensation heater
- Oversize and premium generators
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Control Panels
- Generator temperature monitoring & protection
- Digital I/O module
- Load share module
- EMCP 4.4
- Remote monitoring software
- Mounting
- Spring type vibration isolators
- IBC isolators
- Rubber anti-vibration mounts
- Starting/charging
- Oversize batteries
- Charging alternator
- Heavy duty starting system
- Jacket water heater
- Air starting motor with control and silencer
- Battery chargers
- General
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EU Certificate of Conformance (CE)
- The following options are based on regional and product configuration:
- Enclosures: Sound attenuated, weather protective
- Automatic transfer switches (ATS)
- UL 2200 package
- Integral & sub-base UL listed dual wall fuel tanks
- Integral & sub-base fuel tanks
- EEC Declaration of Conformity
- CSA Certification