Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
- Maximum Rating
- 3125 kVA
- Minimum Rating
- 2250 kVA
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 2 - 1808 rpm
- Voltage
- 380 to 11000 Volts
- Frequency
- 50 Hz
- Speed
- 1808 rpm
- Duty Cycle
- Standby, Mission Critical
Engine Specifications
- Engine Model
- 3516C, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69in
- Stroke
- 8.46in
- Displacement
- 4765in³
- Compression Ratio
- 14.7:1
- Aspiration
- ATAAC
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™A3
Generator Set Dimensions
- Length - Minimum
- 332.3in
- Length - Maximum
- 336.2in
- Width - Maximum
- 100.5in
- Height - Maximum
- 136.9in
- Dry Weight - Genset (minimum)
- 46077lb
- Dry Weight - Genset (maximum)
- 47620lb
Standard Equipment:
- Air Inlet System
- Air cleaner; single element canister type
- Cooling
- Package mounted radiator
- Exhaust
- Exhaust flange outlet
- Fuel
- Primary fuel filter with integral water separator
- Fuel priming pump
- Generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Power Termination
- Busbar
- Control Panel
- Cat Genset controller
- Control System
- 24 Volt DC operation
- EMCP 4.2B
- Environmental sealed front face
- RFI suppression
- Caterpillar's voltage regulator
- Emergency stop pushbutton
- 3 Phase voltage sensing
- Generator set packages include:
- Text alarm/event descriptions
- Generator mounted - rear facing
- KVAR / PF modes
- IVR includes reactive droop capability
- Min / max exciter
- Limiter and exciter diode monitor
- Speed adjust
- Controls:
- Engine cycle crank
- Auto/start/stop control
- Alarm acknowledge
- Engine cool
- PLC functionality
- Load histogram feature
- Lamp test
- Customizable screens
- Digital indication for:
- 3 Phase
- RPM
- 0 True RMS AC metering
- +/- 2% accuracy
- DC volts
- Operating hours
- Coolant temperature
- Amps (per phase & average)
- Volts (L-L & L-N)
- Oil pressure (psi, kPa or bar)
- Power factor (per phase & average)
- Frequency (Hz)
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- kW (per phase, average & percent)
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
- kVAr-hr (total)
- Low oil pressure
- kW-hr (total)
- Cat connect
- Failure to start (overcrank)
- Overcurrent (50/51)
- Communications:
- Low coolant temperature
- Reverse reactive power (kVAr) (32RV)
- Low coolant level
- 6 Customer programmable digital inputs
- 1 Programmable relay outputs (Form C)
- High coolant temperature
- 4 Programmable relay outputs (Form A)
- Programmable protective relaying functions:
- Number of I/O varies on options selected
- 1 Programmable digital outputs
- Serial annunciator module data link
- Accessory module data link
- Over/under frequency (81 o/u)
- Over/under voltage (27/59)
- Overspeed
- 3 Analog inputs
- Generator phase sequence
- Reverse power (kW) (32)
- Governing System
- ADEM A3
- Cooling System
- Certified standard PGS provided
- Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
- Fuel System
- Flexible fuel lines - shipped loose
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- General
- Right hand servicing
- Paint - Caterpillar yellow except rails and radiators gloss black
- Flywheel and flywheel housing - SAE No. 00
- Caterpillar yellow with high gloss black rails and radiator
- SAE standard rotation
- Generator And Attachments
- Permanent magnet excitation (PMG)
- Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
- Winding temperature detectors
- Permanent magnet excitation (PMG)
- Busbar connections, right side extension box, bottom cable entry
- 6 Lead
- Form wound
- NEMA standard hole pattern
- Medium voltage:
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- High voltage:
- Anti-condensation space heater
- 3 Phase brushless, Salient pole
- Literature
- Parts book
- Lubrication System
- Integral lube oil cool
- Gear type lube oil pump
- Fumes disposal
- Oil drain lines and valve
- Oil filter, filler and dipstick
- Lubricating oil
- Mounting System
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
- Rails - Engine/generator/radiator mounting
- Starting System
- Battery disconnect switch
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery and battery rack w/cables
Optional Equipment:
- Control System
- EMCP 4.4
- Air Inlet System
- Dual element air cleaner
- Single element filter
- Exhaust
- Exhaust mufflers
- Generator
- Anti-condensation heater
- Oversize and premium generators
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Cooling System
- Standard ambient radiators
- Coolant
- Optional installed ATAAC radiators
- Optional installed radiators
- Water level switch gauges
- Standard ambient ATAAC radiators
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Crankcase System
- No explosion relief valves
- Explosion relief valves
- Ventilation system
- Control Panels
- Load share module
- Digital I/O module
- Generator temperature monitoring & protection
- Remote monitoring software
- Mounting
- IBC isolators
- Exhaust System
- Y Adapters
- Mufflers
- Exhaust offset
- Flexible fittings
- Tier 4 clean emission MOD Kits
- Flange and exhaust expanders
- Elbows
- Tier 4 clean emissions module
- Clean emission parts
- Tier 4 dosing cabinet
- Flanges
- Starting/charging
- Oversize batteries
- Air starting motor with control and silencer
- Battery chargers
- Heavy duty starting system
- Charging alternator
- Jacket water heater
- Fuel System
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
- General
- The following options are based on regional and product configuration:
- UL 2200 package
- Enclosures: Sound attenuated, weather protective
- EEC Declaration of Conformity
- US aid emblem
- CSA Certification
- Integral & sub-base fuel tanks
- EU Certificate of Conformance (CE)
- Integral & sub-base UL listed dual wall fuel tanks
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- Automatic transfer switches (ATS)
- Generators And Attachments
- Generator conversion
- Space heater
- Thermostat for space heater
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Alternator air cleaner
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Instrumentation
- Pyrometer and thermocouples
- Lubrication System
- Lube oil in standard sump
- Oil level regulator
- Prelube pumps
- Mounting System
- Puck style low efficiency isolators
- IBC vibration isolators
- Spring type vibration isolators
- Power Connections
- Neutral ground connections
- Left side power connections
- Low voltage Circuit breakers
- Ground cables between generator and terminal box
- 2700 Frame, four lead, four terminal
- Rear power connections
- Center post busbars
- Right side power connections
- Special Tests / Reports
- Fuel consumption test
- Generator set fuel consumption test
- Generator test report
- Canadian Standards Association certification
- Torsional vibration analysis reports
- PGS Test report @ 1.0 power factor
- IBC Certification
- Standard engine test charge
- PGS Test report @ 0.8 power factor
- OSHPD Certification
- Starting And Charging
- Air pressure regulator
- Air starting motors
- Jacket water heaters
- 10, 20, 35 and 50 Amp Battery chargers
- Starter cover
- Engine barring device
- Electric starting motors
- 24 Volt battery set - Dry
- Extended Service Coverage
- Platinum, Gold and Silver coverage
Specifications
Generator Set Specifications
- Maximum Rating
- 3125 kVA
- Minimum Rating
- 2250 kVA
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 2 - 1808 rpm
- Voltage
- 380 to 11000 Volts
- Frequency
- 50 Hz
- Speed
- 1808 rpm
- Duty Cycle
- Standby, Mission Critical
Engine Specifications
- Engine Model
- 3516C, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69in
- Stroke
- 8.46in
- Displacement
- 4765in³
- Compression Ratio
- 14.7:1
- Aspiration
- ATAAC
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™A3
Generator Set Dimensions
- Length - Minimum
- 332.3in
- Length - Maximum
- 336.2in
- Width - Maximum
- 100.5in
- Height - Maximum
- 136.9in
- Dry Weight - Genset (minimum)
- 46077lb
- Dry Weight - Genset (maximum)
- 47620lb
Standard/Optional Features
Standard Equipment:
- Air Inlet System
- Air cleaner; single element canister type
- Cooling
- Package mounted radiator
- Exhaust
- Exhaust flange outlet
- Fuel
- Primary fuel filter with integral water separator
- Fuel priming pump
- Generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Power Termination
- Busbar
- Control Panel
- Cat Genset controller
- Control System
- 24 Volt DC operation
- EMCP 4.2B
- Environmental sealed front face
- RFI suppression
- Caterpillar's voltage regulator
- Emergency stop pushbutton
- 3 Phase voltage sensing
- Generator set packages include:
- Text alarm/event descriptions
- Generator mounted - rear facing
- KVAR / PF modes
- IVR includes reactive droop capability
- Min / max exciter
- Limiter and exciter diode monitor
- Speed adjust
- Controls:
- Engine cycle crank
- Auto/start/stop control
- Alarm acknowledge
- Engine cool
- PLC functionality
- Load histogram feature
- Lamp test
- Customizable screens
- Digital indication for:
- 3 Phase
- RPM
- 0 True RMS AC metering
- +/- 2% accuracy
- DC volts
- Operating hours
- Coolant temperature
- Amps (per phase & average)
- Volts (L-L & L-N)
- Oil pressure (psi, kPa or bar)
- Power factor (per phase & average)
- Frequency (Hz)
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- kW (per phase, average & percent)
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
- kVAr-hr (total)
- Low oil pressure
- kW-hr (total)
- Cat connect
- Failure to start (overcrank)
- Overcurrent (50/51)
- Communications:
- Low coolant temperature
- Reverse reactive power (kVAr) (32RV)
- Low coolant level
- 6 Customer programmable digital inputs
- 1 Programmable relay outputs (Form C)
- High coolant temperature
- 4 Programmable relay outputs (Form A)
- Programmable protective relaying functions:
- Number of I/O varies on options selected
- 1 Programmable digital outputs
- Serial annunciator module data link
- Accessory module data link
- Over/under frequency (81 o/u)
- Over/under voltage (27/59)
- Overspeed
- 3 Analog inputs
- Generator phase sequence
- Reverse power (kW) (32)
- Governing System
- ADEM A3
- Cooling System
- Certified standard PGS provided
- Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
- Fuel System
- Flexible fuel lines - shipped loose
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- General
- Right hand servicing
- Paint - Caterpillar yellow except rails and radiators gloss black
- Flywheel and flywheel housing - SAE No. 00
- Caterpillar yellow with high gloss black rails and radiator
- SAE standard rotation
- Generator And Attachments
- Permanent magnet excitation (PMG)
- Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
- Winding temperature detectors
- Permanent magnet excitation (PMG)
- Busbar connections, right side extension box, bottom cable entry
- 6 Lead
- Form wound
- NEMA standard hole pattern
- Medium voltage:
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- High voltage:
- Anti-condensation space heater
- 3 Phase brushless, Salient pole
- Literature
- Parts book
- Lubrication System
- Integral lube oil cool
- Gear type lube oil pump
- Fumes disposal
- Oil drain lines and valve
- Oil filter, filler and dipstick
- Lubricating oil
- Mounting System
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
- Rails - Engine/generator/radiator mounting
- Starting System
- Battery disconnect switch
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery and battery rack w/cables
Optional Equipment:
- Control System
- EMCP 4.4
- Air Inlet System
- Dual element air cleaner
- Single element filter
- Exhaust
- Exhaust mufflers
- Generator
- Anti-condensation heater
- Oversize and premium generators
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Cooling System
- Standard ambient radiators
- Coolant
- Optional installed ATAAC radiators
- Optional installed radiators
- Water level switch gauges
- Standard ambient ATAAC radiators
- Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
- Crankcase System
- No explosion relief valves
- Explosion relief valves
- Ventilation system
- Control Panels
- Load share module
- Digital I/O module
- Generator temperature monitoring & protection
- Remote monitoring software
- Mounting
- IBC isolators
- Exhaust System
- Y Adapters
- Mufflers
- Exhaust offset
- Flexible fittings
- Tier 4 clean emission MOD Kits
- Flange and exhaust expanders
- Elbows
- Tier 4 clean emissions module
- Clean emission parts
- Tier 4 dosing cabinet
- Flanges
- Starting/charging
- Oversize batteries
- Air starting motor with control and silencer
- Battery chargers
- Heavy duty starting system
- Charging alternator
- Jacket water heater
- Fuel System
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
- General
- The following options are based on regional and product configuration:
- UL 2200 package
- Enclosures: Sound attenuated, weather protective
- EEC Declaration of Conformity
- US aid emblem
- CSA Certification
- Integral & sub-base fuel tanks
- EU Certificate of Conformance (CE)
- Integral & sub-base UL listed dual wall fuel tanks
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- Automatic transfer switches (ATS)
- Generators And Attachments
- Generator conversion
- Space heater
- Thermostat for space heater
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Alternator air cleaner
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Instrumentation
- Pyrometer and thermocouples
- Lubrication System
- Lube oil in standard sump
- Oil level regulator
- Prelube pumps
- Mounting System
- Puck style low efficiency isolators
- IBC vibration isolators
- Spring type vibration isolators
- Power Connections
- Neutral ground connections
- Left side power connections
- Low voltage Circuit breakers
- Ground cables between generator and terminal box
- 2700 Frame, four lead, four terminal
- Rear power connections
- Center post busbars
- Right side power connections
- Special Tests / Reports
- Fuel consumption test
- Generator set fuel consumption test
- Generator test report
- Canadian Standards Association certification
- Torsional vibration analysis reports
- PGS Test report @ 1.0 power factor
- IBC Certification
- Standard engine test charge
- PGS Test report @ 0.8 power factor
- OSHPD Certification
- Starting And Charging
- Air pressure regulator
- Air starting motors
- Jacket water heaters
- 10, 20, 35 and 50 Amp Battery chargers
- Starter cover
- Engine barring device
- Electric starting motors
- 24 Volt battery set - Dry
- Extended Service Coverage
- Platinum, Gold and Silver coverage