Discontinued 7

Discontinued

Select View:

Items Per Page


Discontinued 8

CTE Series Automatic Transfer Switch
ATS MX Contactor

Rating Range
40-4,000A
Transfer Type
Open / Closed / 4 position switch
Switch Type
Contactor Based
Discontinued 9

CTG Series Automatic Transfer Switch
ATS MX Contactor

Transfer Type
Open transition
Rating Range
40-3,000A
Switch Type
Contactor based
Discontinued 10

CTGSE & CTGDSE Series Service Rated Entrance Rated ATS
ATS MX Contactor

Switch Type
Contactor Based
Transfer Type
Open Transition with Service Entrance
Rating Range
40-3,000A
Discontinued 11

CTS Series Automatic Transfer Switch
ATS MX Contactor

Rating Range
40 to 4,000A
Transfer Type
Open transition
Switch Type
Contactor Based
Discontinued 12

CTSM and CTGM Series Manual Transfer Switches
ATS MX Contactor

Rating Range
40-4,000A
Transfer Type
Open / Manual
Switch Type
Contactor Based
Discontinued 13

MX150 Microprocessor Controller
ATS MX Contactor

Rating Range
Switch Dependent
Transfer Type
Application Dependent
Switch Type
Application Dependent
Discontinued 14

MX250 Microprocessor Controller
ATS MX Contactor

Rating Range
Switch Dependent
Transfer Type
Application Dependent
Switch Type
Application Dependent
Discontinued 15

MX350 Controller
ATS MX Contactor

Voltage Unbalance on Dropout for Source 1 and Source 2
5 to 20% of nominal
Delay NeutralTransition Time Delays (DT,DW)
0-10 minutes
Control Power
120 VAC
Discontinued 16

C32
Commercial Propulsion Engines

Power Range
660-1,600 bhp (492-1,193 bkW)
Speed Range
1,600-2,300 rpm
Emissions
U.S. EPA Tier 3 / IMO II emissions certified
Discontinued 17

C32 Tier 4 / IMO III
Commercial Propulsion Engines

Power Range
1,000-1,450 bhp (746-1,081 bKW)
Speed Range
1,600-2,150 rpm
6 Brick Z-Flow - Length
147.7 in
Discontinued 18

3508C
Commercial Propulsion Engines

Power Range
775-1,100 bhp (578-820 bkW)
Speed Range
1,200-1,600 rpm
Emissions
IMO II, EU IW
Discontinued 19

3512C Tier 3
Commercial Propulsion Engines

Power Range
1,340-2,366 bhp (1,000-1,765 bkW)
Speed Range
1,600-1,800 rpm
Emissions
EPA Tier 3, IMO II
Discontinued 20

3516C Tier 3
Commercial Propulsion Engines

Power Range
2,131-2,675 bhp (1,590-1,995 bkW)
Speed Range
1,600 rpm
Emissions
EPA Tier 3, IMO II
Discontinued 21

C280-8 Tier 4/ IMO III
Commercial Propulsion Engines

Power Range
3,299-3,634 bhp (2,460-2,530 bkW)
Speed Range
1,000 rpm
Emissions
EPA Tier 4, IMO III
Discontinued 22

C280-12
Commercial Propulsion Engines

Power Range
4,640-5,096 bhp (3,460-3,800 bkW)
Speed Range
900 rpm
Emissions
IMO II
Discontinued 23

C18
High Performance Propulsion and Maneuvering Solutions

Power Range
803 - 1,136 bhp, 599 - 847 bkW
Speed Range
2,100-2,300 rpm
Emissions
EPA Tier 3, IMO II
Discontinued 24

C32 Tier 3 / IMO II
Marine Generator Sets

Minimum Rating
219 ekW
Maximum Rating
940 ekW
Frequency
60hz
Discontinued 25

C32 Tier 4 / IMO III
Marine Generator Sets

Minimum Rating
282 ekW
Maximum Rating
940 ekW
Frequency
60hz
Discontinued 26

C32
Auxiliary Engines

Power Range
791-1,333
Rated Engine Speed
1,500 / 1,800
Emissions
IMO II, IMO III, U.S. Tier 4, EU Stage V, China II
Discontinued 27

C32 Tier 3 / IMO II
Auxiliary Engines

Minimum Rating
314 BHP
Maximum Rating
1,333 BHP
Aspiration
Turbocharged-aftercooled aspiration
Discontinued 28

C32 Tier 4 / IMO III
Auxiliary Engines

Minimum Rating
400 BHP
Maximum Rating
1,333 BHP
Aspiration
Turbocharged-aftercooled
Discontinued 29

BA118C Hydraulic, Polypropylene/Wire
Angle Brooms

Overall Width
103.8 in
Sweeping Width
83.4 in
Brush Diameter
32.1 in
Discontinued 33

BU115
Utility Brooms

Overall Width
71.3 in
Sweeping Width
59.4 in
Brush Diameter
26 in
Discontinued 37

0.9 m3 (1.2 yd3), Skid Steer Coupler, Bolt-On Teeth
General Purpose Buckets

Width
74 in
Weight
822.1 lb
Height
36.2 in