Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
|
|
|
|
Generator Set Specifications
- Maximum Rating
- 850 kVA
- Minimum Rating
- 706 kVA
- Emissions/Fuel Strategy
- Low Fuel
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1,500
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
- Bore
- 5.71 in
- Stroke
- 7.2 in
- Displacement
- 1,106.4 in³
- Compression Ratio
- 14.5:1
- Aspiration
- Air to Air Aftercooled
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Maximum
- 162.4 in
- Width - Maximum
- 78.3 in
- Height - Maximum
- 75 in
Standard Equipment:
-
- Air Inlet System
-
- Single element air cleaner
- Turbocharger
- Aftercooler core
- Light duty air cleaner
-
- Control System
-
- GCCP 1.3
-
- Cooling
-
- Coolant drain line with valve
- Radiator and cooling fan with guard
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
-
- Exhaust System
-
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
-
- Fuel System
-
- Standard 8 hour open set integral fuel tank
-
- Generator And Attachments
-
- LC frame generator - IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Segregated low voltage (AC/DC) wiring panel
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Integrated voltage regulator (IVR)
- Power center, IP22
- Integrated voltage regulator (IVR)
-
- Governing System
-
- Cat electronic governor (ADEM A4)
-
- Lube System
-
- Lubricating oil
- Oil drain lines with valves
-
- Mounting System
-
- Captive linear vibration isolators between base and engine-generator.
-
- Starting/charging
-
- 24 Volt battery with rack and cables
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Air Inlet System
-
- Dual element air cleaner
-
- Circuit Breakers
-
- 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
- Circuit breaker (IEC) Auxiliary contacts
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
- Padlockable circuit breaker device
- Shunt trip for IEC breaker
- Power terminal strip
- 4 Pole (IEC-100% rated) Circuit breakers - Motorised
- 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
-
- Control System
-
- Local alarm horn
- Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
- GCCP 1.4
- Remote annunciator module
- Oil temperature displays
- Local alarm modules
-
- Cooling System
-
- Radiator transition flange
- Low coolant temperature alarm
-
- Enclosures
-
- Sound attenuated enclosures (to be available soon)
-
- Exhaust System
-
- 8 and 10 inch elbow kits
- 10, 25, 35 dB end in / end out mufflers
- Engine mounted muffler
- 8 and 10 inch GP flanges
- Manifold and turbocharger guards
-
- Fuel System
-
- Integral - Dual wall fuel tank base
- Fuel transfer system
- Manual fuel transfer pump
-
- Generator And Attachments
-
- Space heaters
- A Frame CIP generator
- LC frame CIP generator
- A Frame oversize generator
- Ingress protection
- LC frame oversize generators
- LC frame generator
- Permanent magnet excitation (PMG)
-
- Lube System
-
- Manual sump pump
-
- Starting And Charging
-
- Jacket water heaters
- 5 Amp Battery charger
- Battery disconnect switch
- Jacket water heaters
Specifications
Generator Set Specifications
- Maximum Rating
- 850 kVA
- Minimum Rating
- 706 kVA
- Emissions/Fuel Strategy
- Low Fuel
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1,500
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
- Bore
- 5.71 in
- Stroke
- 7.2 in
- Displacement
- 1,106.4 in³
- Compression Ratio
- 14.5:1
- Aspiration
- Air to Air Aftercooled
- Fuel System
- Electronic unit injection
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Maximum
- 162.4 in
- Width - Maximum
- 78.3 in
- Height - Maximum
- 75 in
Standard/Optional Features
Standard Equipment:
-
- Air Inlet System
-
- Single element air cleaner
- Turbocharger
- Aftercooler core
- Light duty air cleaner
-
- Control System
-
- GCCP 1.3
-
- Cooling
-
- Coolant drain line with valve
- Radiator and cooling fan with guard
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
-
- Exhaust System
-
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
-
- Fuel System
-
- Standard 8 hour open set integral fuel tank
-
- Generator And Attachments
-
- LC frame generator - IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Segregated low voltage (AC/DC) wiring panel
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Integrated voltage regulator (IVR)
- Power center, IP22
- Integrated voltage regulator (IVR)
-
- Governing System
-
- Cat electronic governor (ADEM A4)
-
- Lube System
-
- Lubricating oil
- Oil drain lines with valves
-
- Mounting System
-
- Captive linear vibration isolators between base and engine-generator.
-
- Starting/charging
-
- 24 Volt battery with rack and cables
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Air Inlet System
-
- Dual element air cleaner
-
- Circuit Breakers
-
- 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
- Circuit breaker (IEC) Auxiliary contacts
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
- Padlockable circuit breaker device
- Shunt trip for IEC breaker
- Power terminal strip
- 4 Pole (IEC-100% rated) Circuit breakers - Motorised
- 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
-
- Control System
-
- Local alarm horn
- Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
- GCCP 1.4
- Remote annunciator module
- Oil temperature displays
- Local alarm modules
-
- Cooling System
-
- Radiator transition flange
- Low coolant temperature alarm
-
- Enclosures
-
- Sound attenuated enclosures (to be available soon)
-
- Exhaust System
-
- 8 and 10 inch elbow kits
- 10, 25, 35 dB end in / end out mufflers
- Engine mounted muffler
- 8 and 10 inch GP flanges
- Manifold and turbocharger guards
-
- Fuel System
-
- Integral - Dual wall fuel tank base
- Fuel transfer system
- Manual fuel transfer pump
-
- Generator And Attachments
-
- Space heaters
- A Frame CIP generator
- LC frame CIP generator
- A Frame oversize generator
- Ingress protection
- LC frame oversize generators
- LC frame generator
- Permanent magnet excitation (PMG)
-
- Lube System
-
- Manual sump pump
-
- Starting And Charging
-
- Jacket water heaters
- 5 Amp Battery charger
- Battery disconnect switch
- Jacket water heaters