fbpx

D400 GC (60 Hz) Generator Set 11177

D400 GC (60 Hz) Generator Set
11177 D400 GC (60 Hz) Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Electric Power
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
400 ekW
Minimum Rating
400 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
480 to 600 Volts

Generator Set Specifications

Maximum Rating
400 ekW
Minimum Rating
400 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
480 to 600 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C13 In-line 6, 4-cycle diesel
Bore
5.1 in
Stroke
6.2 in
Displacement
763 in³
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
MEUI
Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum
182.8 in
Width - Maximum
64.2 in
Height - Minimum
80.3 in
Height - Maximum
96.7 in
Dry Weight - Genset (minimum)
7,330.4 lb
Dry Weight - Genset (maximum)
4,107 lb

Standard Equipment:

  • Air Inlet System
    • Air cleaner - Non canister, disposable
    • Aftercooler core
    • Turbocharger
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Blower fan and fan drive with guards
    • Coolant drain valve
    • Radiator sight gauge
    • Radiator, package mounted
    • Jacket water pump, gear driven, centrifugal
    • Thermostats and housing
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Engine fuel transfer pump
    • Fuel cooler
    • Fuel priming pump
    • Integral tank base, 24 hours, UL142
  • Generator Set
    • All protective devices and control functions simulated and checked
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • Factory tested to design specifications at full load conditions
  • Generators And Generator Attachments
    • Insulation system, Class H
    • IP23 Protection
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • 6 Leads
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Easy access to AVR and terminals
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    • Voltage regulator (single phase sensing)
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Fumes disposal to front of radiator
    • Lubricating oil, CK-4 (10W-30)
    • Oil cooler
    • Shallow oil pan
    • Oil filler and dipstick
    • Oil filter, spin on
    • Oil drain with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - Low oil pressure
    • Safety shutoff - High water temperature
    • Safety shutoff - Overspeed
  • Starting/charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book

Optional Equipment:

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Audio & visual fuel alarm (@90% fuel level)
    • Integral tank base, 24 hours, UL142
    • 5 Gallon Spill Containment
    • Fuel tank pill pipe & lockable cap
    • Overfill prevention valve
    • Wide Base - Skid
  • Circuit Breaker
    • 1200A LSI
    • 1200A LS/I
    • 600A LS/I
    • 400A LS/I
    • 800A LS/I
    • 600A LSI
    • Auxiliary contacts
    • 800A LSI
    • 400A LSI
  • Control System
    • Twist release, Red button emergency stop
    • Ground fault relay
    • Volt free contacts
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • 100A Load center
    • Product link remote monitoring hardware
  • Enclosures
    • AC & DC Source lights
    • E-Stop
    • Sound attenuated Level 2 enclosure (White)
  • Exhaust System
    • 8" Muffler - 25 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust connection
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Circuit Breakers
    • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
    • Circuit breaker (IEC) Auxiliary contacts
    • Shunt trip for IEC circuit breaker
  • Starting System
    • Oversize battery set, 1400 CCA, 200 amp/hr
    • Standard battery set: 1000 CCA, 90 amp/hr.
    • Jacket water heater
    • Battery charger (UL Certified)
  • General
    • Generator test report
    • Extended Service Coverage
    • UL2200 Certification
    • CSA Certification
  • Starting / Charging System
    • Jacket water heater
    • Battery disconnect switch

Specifications

Generator Set Specifications

Maximum Rating
400 ekW
Minimum Rating
400 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
480 to 600 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C13 In-line 6, 4-cycle diesel
Bore
5.1 in
Stroke
6.2 in
Displacement
763 in³
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
MEUI
Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum
182.8 in
Width - Maximum
64.2 in
Height - Minimum
80.3 in
Height - Maximum
96.7 in
Dry Weight - Genset (minimum)
7,330.4 lb
Dry Weight - Genset (maximum)
4,107 lb

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Air cleaner - Non canister, disposable
    • Aftercooler core
    • Turbocharger
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Blower fan and fan drive with guards
    • Coolant drain valve
    • Radiator sight gauge
    • Radiator, package mounted
    • Jacket water pump, gear driven, centrifugal
    • Thermostats and housing
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Engine fuel transfer pump
    • Fuel cooler
    • Fuel priming pump
    • Integral tank base, 24 hours, UL142
  • Generator Set
    • All protective devices and control functions simulated and checked
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • Factory tested to design specifications at full load conditions
  • Generators And Generator Attachments
    • Insulation system, Class H
    • IP23 Protection
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • 6 Leads
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Easy access to AVR and terminals
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    • Voltage regulator (single phase sensing)
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Fumes disposal to front of radiator
    • Lubricating oil, CK-4 (10W-30)
    • Oil cooler
    • Shallow oil pan
    • Oil filler and dipstick
    • Oil filter, spin on
    • Oil drain with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - Low oil pressure
    • Safety shutoff - High water temperature
    • Safety shutoff - Overspeed
  • Starting/charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book

Optional Equipment:

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Audio & visual fuel alarm (@90% fuel level)
    • Integral tank base, 24 hours, UL142
    • 5 Gallon Spill Containment
    • Fuel tank pill pipe & lockable cap
    • Overfill prevention valve
    • Wide Base - Skid
  • Circuit Breaker
    • 1200A LSI
    • 1200A LS/I
    • 600A LS/I
    • 400A LS/I
    • 800A LS/I
    • 600A LSI
    • Auxiliary contacts
    • 800A LSI
    • 400A LSI
  • Control System
    • Twist release, Red button emergency stop
    • Ground fault relay
    • Volt free contacts
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • 100A Load center
    • Product link remote monitoring hardware
  • Enclosures
    • AC & DC Source lights
    • E-Stop
    • Sound attenuated Level 2 enclosure (White)
  • Exhaust System
    • 8" Muffler - 25 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust connection
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Circuit Breakers
    • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
    • Circuit breaker (IEC) Auxiliary contacts
    • Shunt trip for IEC circuit breaker
  • Starting System
    • Oversize battery set, 1400 CCA, 200 amp/hr
    • Standard battery set: 1000 CCA, 90 amp/hr.
    • Jacket water heater
    • Battery charger (UL Certified)
  • General
    • Generator test report
    • Extended Service Coverage
    • UL2200 Certification
    • CSA Certification
  • Starting / Charging System
    • Jacket water heater
    • Battery disconnect switch