fbpx

DE110 GC Generator Set (50 Hz) 16832

DE110 GC Generator Set (50 Hz)
16832 DE110 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
110 kVA
Minimum Rating
110 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
110 kVA
Minimum Rating
110 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
18.23:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
108.1in
Width - Maximum
39.3in
Height - Maximum
58.1in
Dry Weight - Genset (maximum)
1330lb

Standard Equipment:

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Alternator
    • A Frame standard alternator
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance 13
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • High fuel level alarm
    • Low fuel level alarm
    • Low fuel level shutdown
  • Genset Control
    • Volt free contacts for common alarm
    • Panel mounted audible alarm
    • Earth fault
    • Volt free contacts for genset running
    • Emergency stop with key
    • Earth leakage
    • Battery charger
    • USB to RS485 Communications device
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
110 kVA
Minimum Rating
110 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
18.23:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
108.1in
Width - Maximum
39.3in
Height - Maximum
58.1in
Dry Weight - Genset (maximum)
1330lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Alternator
    • A Frame standard alternator
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance 13
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • High fuel level alarm
    • Low fuel level alarm
    • Low fuel level shutdown
  • Genset Control
    • Volt free contacts for common alarm
    • Panel mounted audible alarm
    • Earth fault
    • Volt free contacts for genset running
    • Emergency stop with key
    • Earth leakage
    • Battery charger
    • USB to RS485 Communications device
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF