fbpx

DE110 GC Generator Set (60 Hz) 16834

DE110 GC Generator Set (60 Hz)
16834 DE110 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
18.23:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
108.1in
Width - Maximum
39.3in
Height - Maximum
58.1in
Dry Weight - Genset (maximum)
2932lb

Standard Equipment:

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Emergency stop with key
    • Battery charger
    • Earth fault
    • USB to RS485 Communications device
    • Panel mounted audible alarm
    • Earth leakage
    • Volt free contacts for common alarm
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Circuit Breaker
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
100 ekW
Minimum Rating
100 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
18.23:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
108.1in
Width - Maximum
39.3in
Height - Maximum
58.1in
Dry Weight - Genset (maximum)
2932lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance 13
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Emergency stop with key
    • Battery charger
    • Earth fault
    • USB to RS485 Communications device
    • Panel mounted audible alarm
    • Earth leakage
    • Volt free contacts for common alarm
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Circuit Breaker
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF