fbpx

DE150 GC Generator Set (60 Hz) 16840

DE150 GC Generator Set (60 Hz)
16840 DE150 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
132 ekW
Minimum Rating
132 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
132 ekW
Minimum Rating
132 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
Stroke
5.3 in
Displacement
427.8 in³
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9 in
Width - Maximum
44.6 in
Height - Maximum
65.6 in
Dry Weight - Genset (maximum)
4,043 lb

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Alternator
    • A Frame standard alternator
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level alarm
    • High fuel level alarm
    • Low fuel level shutdown
    • Single wall tank with containment
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Genset Control
    • Panel mounted audible alarm
    • Battery charger
    • Earth leakage
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
132 ekW
Minimum Rating
132 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
Stroke
5.3 in
Displacement
427.8 in³
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9 in
Width - Maximum
44.6 in
Height - Maximum
65.6 in
Dry Weight - Genset (maximum)
4,043 lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Alternator
    • A Frame standard alternator
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level alarm
    • High fuel level alarm
    • Low fuel level shutdown
    • Single wall tank with containment
  • Circuit Breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Genset Control
    • Panel mounted audible alarm
    • Battery charger
    • Earth leakage
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF