Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
|
|
|
|
Generator Set Specifications
- Maximum Rating
- 132 ekW
- Minimum Rating
- 132 ekW
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 220 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C7.1 I-6, 4-Cycle Diesel
- Bore
- 4.1 in
- Stroke
- 5.3 in
- Displacement
- 427.8 in³
- Compression Ratio
- 18.2:1
- Aspiration
- Turbocharged
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length - Maximum
- 130.9 in
- Width - Maximum
- 44.6 in
- Height - Maximum
- 65.6 in
- Dry Weight - Genset (maximum)
- 4,043 lb
Standard Equipment:
-
- Engine
-
- C7.1, Inline 6 cylinder, 4 stroke diesel
-
- Control Panels
-
- GCCP 1.1
-
- Fuel Storage
-
- Single wall 8 hour fuel tank
-
- Governor
-
- Mechanical governor
-
- Enclosure
-
- Cat GC enclosure
-
- Alternator
-
- A Frame standard alternator
-
- Air, Cooling & Exhaust
-
- Enclosure silencer
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Auxiliary Supply Voltage
-
- 120V
-
- Certification
-
- Certificate of Conformance
- Australia, CIS, Gulf Certification
-
- Alternator Requirements
-
- Space heater
-
- Fuel Storage
-
- Dual wall 8 hour fuel tank
- Low fuel level alarm
- High fuel level alarm
- Low fuel level shutdown
- Single wall tank with containment
-
- Circuit Breaker
-
- 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 250A
- 4 Pole Circuit breaker 200A
- 3 Pole Circuit breaker 250A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 630A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 400A
-
- Genset Control
-
- Panel mounted audible alarm
- Battery charger
- Earth leakage
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Earth fault
- Emergency stop with key
- USB to RS485 Communications device
- Coolant heater
- Battery
- Low coolant level shutdown
- Standby Pack (Smart Jacket water heater, Battery charger)
-
- Testing & Packaging
-
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF
Specifications
Generator Set Specifications
- Maximum Rating
- 132 ekW
- Minimum Rating
- 132 ekW
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 220 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C7.1 I-6, 4-Cycle Diesel
- Bore
- 4.1 in
- Stroke
- 5.3 in
- Displacement
- 427.8 in³
- Compression Ratio
- 18.2:1
- Aspiration
- Turbocharged
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length - Maximum
- 130.9 in
- Width - Maximum
- 44.6 in
- Height - Maximum
- 65.6 in
- Dry Weight - Genset (maximum)
- 4,043 lb
Standard/Optional Features
Standard Equipment:
-
- Engine
-
- C7.1, Inline 6 cylinder, 4 stroke diesel
-
- Control Panels
-
- GCCP 1.1
-
- Fuel Storage
-
- Single wall 8 hour fuel tank
-
- Governor
-
- Mechanical governor
-
- Enclosure
-
- Cat GC enclosure
-
- Alternator
-
- A Frame standard alternator
-
- Air, Cooling & Exhaust
-
- Enclosure silencer
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Auxiliary Supply Voltage
-
- 120V
-
- Certification
-
- Certificate of Conformance
- Australia, CIS, Gulf Certification
-
- Alternator Requirements
-
- Space heater
-
- Fuel Storage
-
- Dual wall 8 hour fuel tank
- Low fuel level alarm
- High fuel level alarm
- Low fuel level shutdown
- Single wall tank with containment
-
- Circuit Breaker
-
- 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 250A
- 4 Pole Circuit breaker 200A
- 3 Pole Circuit breaker 250A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 630A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 400A
-
- Genset Control
-
- Panel mounted audible alarm
- Battery charger
- Earth leakage
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Earth fault
- Emergency stop with key
- USB to RS485 Communications device
- Coolant heater
- Battery
- Low coolant level shutdown
- Standby Pack (Smart Jacket water heater, Battery charger)
-
- Testing & Packaging
-
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF