fbpx

DE200 GC Generator Set (50 Hz) 16843

DE200 GC Generator Set (50 Hz)
16843 DE200 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
200 kVA
Minimum Rating
200 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
200 kVA
Minimum Rating
200 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4257lb

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Alternator
    • A Frame standard alternator
  • Governor
    • Mechanical governor
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level alarm
    • Low fuel level shutdown
    • High fuel level alarm
  • Genset Control
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Battery charger
    • Earth leakage
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth fault
    • Coolant heater
    • Low coolant level shutdown
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Circuit Breaker
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 630A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
200 kVA
Minimum Rating
200 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
4.1in
Stroke
5.3in
Displacement
427.8in³
Compression Ratio
16.0:1
Aspiration
Turbocharged Air To Air Charge Cooled
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
130.9in
Width - Maximum
44.6in
Height - Maximum
65.6in
Dry Weight - Genset (maximum)
4257lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Alternator
    • A Frame standard alternator
  • Governor
    • Mechanical governor
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level alarm
    • Low fuel level shutdown
    • High fuel level alarm
  • Genset Control
    • Panel mounted audible alarm
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Battery charger
    • Earth leakage
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth fault
    • Coolant heater
    • Low coolant level shutdown
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Circuit Breaker
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 630A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF