fbpx

DE33 GC Generator Set (60 Hz) 16815

DE33 GC Generator Set (60 Hz)
16815 DE33 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
30.0 ekW
Minimum Rating
30.0 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
30.0 ekW
Minimum Rating
30.0 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
201.4 in³
Compression Ratio
19.25:1
Aspiration
Naturally Aspirated
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
76.6 in
Width - Maximum
34.3 in
Height - Maximum
48.7 in
Dry Weight - Genset (maximum)
2,114 lb

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Panel mounted audible alarm
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth leakage
    • Low coolant level shutdown
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
  • Circuit Breaker
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor

Specifications

Generator Set Specifications

Maximum Rating
30.0 ekW
Minimum Rating
30.0 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
201.4 in³
Compression Ratio
19.25:1
Aspiration
Naturally Aspirated
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
76.6 in
Width - Maximum
34.3 in
Height - Maximum
48.7 in
Dry Weight - Genset (maximum)
2,114 lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Panel mounted audible alarm
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth leakage
    • Low coolant level shutdown
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
  • Circuit Breaker
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor