Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
|
|
|
|
Generator Set Specifications
- Maximum Rating
- 400 ekW
- Minimum Rating
- 400 ekW
- Emissions/Fuel Strategy
- Low Fuel, R96/EUIIIa
- Voltage
- 220 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
- Bore
- 4.53 in
- Stroke
- 5.87 in
- Displacement
- 567.5 in³
- Compression Ratio
- 16.5:1
- Aspiration
- Air to Air Aftercooled
- Fuel System
- Direct Injection
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Maximum
- 186.7 in
- Width - Maximum
- 79.3 in
- Height - Maximum
- 84 in
Standard Equipment:
-
- Engine
-
- C9.3B, Inline 6 cylinder, 4 stroke diesel
-
- Genset Control
-
- GCCP 1.1
-
- Governor
-
- Adem A4
-
- Alternator
-
- A Frame standard alternator
-
- Fuel Storage
-
- Single wall 8 hour fuel tank
-
- Air, Cooling & Exhaust
-
- Standard air filter
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- European Certificates
-
- Australia, CIS, Gulf Certification
- EU Certificate of Conformance (CE)
-
- Auxiliary Supply Voltage
-
- 240V
-
- Alternator Requirements
-
- Space heater
- IP Standard @ 21 FUW A-Frame
-
- Fuel Storage
-
- High fuel level alarm
- Dual wall 8 hour fuel tank
- Single wall tank with containment 01
- Fuel level sender
- Low fuel level shutdown
- Low fuel level alarm
-
- Enclosure
-
- Cat GC enclosure
-
- Genset Control
-
- Speed adjust potentiometer
- Battery charger
- Standby Pack (Smart Jacket water heater, Battery charger)
- Voltage adjust potentiometer
- PLG Cellular 4G E
- Low coolant temperature alarm
- Battery
- Oil temperature displays
- PLG Cellular 4G U
- Coolant heater
- PLG Ethernet
-
- Circuit Breaker
-
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 1250A
- Neutral earth link
- 4 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 1250A
- 4 Pole Circuit breaker 800A
- Circuit breaker padlock
- Auxiliary contacts
- 3 Pole Circuit breaker 800A
- Shunt Trip
- 3 Pole Circuit breaker 630A
-
- Air, Cooling & Exhaust
-
- 6" Elbow kit
- 6" Elbow kit
- 5" Elbow kit
- 5-6" Exhaust adapter
- Canopy silencer
- 6" Muffler - 25 dBA attenuation
- Dual element air filter
- Single stage air filter
- No muffler
- 5" Muffler - 10 dBA Attenuation
Specifications
Generator Set Specifications
- Maximum Rating
- 400 ekW
- Minimum Rating
- 400 ekW
- Emissions/Fuel Strategy
- Low Fuel, R96/EUIIIa
- Voltage
- 220 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1,800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
- Bore
- 4.53 in
- Stroke
- 5.87 in
- Displacement
- 567.5 in³
- Compression Ratio
- 16.5:1
- Aspiration
- Air to Air Aftercooled
- Fuel System
- Direct Injection
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length - Maximum
- 186.7 in
- Width - Maximum
- 79.3 in
- Height - Maximum
- 84 in
Standard/Optional Features
Standard Equipment:
-
- Engine
-
- C9.3B, Inline 6 cylinder, 4 stroke diesel
-
- Genset Control
-
- GCCP 1.1
-
- Governor
-
- Adem A4
-
- Alternator
-
- A Frame standard alternator
-
- Fuel Storage
-
- Single wall 8 hour fuel tank
-
- Air, Cooling & Exhaust
-
- Standard air filter
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- European Certificates
-
- Australia, CIS, Gulf Certification
- EU Certificate of Conformance (CE)
-
- Auxiliary Supply Voltage
-
- 240V
-
- Alternator Requirements
-
- Space heater
- IP Standard @ 21 FUW A-Frame
-
- Fuel Storage
-
- High fuel level alarm
- Dual wall 8 hour fuel tank
- Single wall tank with containment 01
- Fuel level sender
- Low fuel level shutdown
- Low fuel level alarm
-
- Enclosure
-
- Cat GC enclosure
-
- Genset Control
-
- Speed adjust potentiometer
- Battery charger
- Standby Pack (Smart Jacket water heater, Battery charger)
- Voltage adjust potentiometer
- PLG Cellular 4G E
- Low coolant temperature alarm
- Battery
- Oil temperature displays
- PLG Cellular 4G U
- Coolant heater
- PLG Ethernet
-
- Circuit Breaker
-
- Overload via alarm switch on breaker
- 3 Pole Circuit breaker 1250A
- Neutral earth link
- 4 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 1250A
- 4 Pole Circuit breaker 800A
- Circuit breaker padlock
- Auxiliary contacts
- 3 Pole Circuit breaker 800A
- Shunt Trip
- 3 Pole Circuit breaker 630A
-
- Air, Cooling & Exhaust
-
- 6" Elbow kit
- 6" Elbow kit
- 5" Elbow kit
- 5-6" Exhaust adapter
- Canopy silencer
- 6" Muffler - 25 dBA attenuation
- Dual element air filter
- Single stage air filter
- No muffler
- 5" Muffler - 10 dBA Attenuation