fbpx

DE50 GC Generator Set (60 Hz) 16819

DE50 GC Generator Set (60 Hz)
16819 DE50 GC Generator Set (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
45 ekW
Duty Cycle
Standby
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
45 ekW
Duty Cycle
Standby
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Minimum Rating
45 ekW

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
201.4 in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
89.7 in
Width - Maximum
35.4 in
Height - Maximum
52 in
Dry Weight - Genset (maximum)
1,031 lb

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Earth leakage
    • Earth fault
    • USB to RS485 Communications device
    • Emergency stop with key
    • Panel mounted audible alarm
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
45 ekW
Duty Cycle
Standby
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 rpm
Minimum Rating
45 ekW

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
201.4 in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
89.7 in
Width - Maximum
35.4 in
Height - Maximum
52 in
Dry Weight - Genset (maximum)
1,031 lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Earth leakage
    • Earth fault
    • USB to RS485 Communications device
    • Emergency stop with key
    • Panel mounted audible alarm
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF