fbpx

DE600S GC Generator Set 16872

DE600S GC Generator Set
16872 DE600S GC Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
600 ekW
Minimum Rating
600 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts

Generator Set Specifications

Maximum Rating
600 ekW
Minimum Rating
600 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 RPM
Duty Cycle
Standby

Engine Specifications

Engine Model
C15 In-line 6, 4-cycle diesel
Bore
5.4 in
Stroke
6.8 in
Displacement
928 in³
Compression Ratio
16.1:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
EUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
131 in
Width - Maximum
60.6 in
Height - Maximum
86.1 in
Dry Weight - Genset (maximum)
8,364 lb

Standard Equipment:

  • Engine
    • Cat® C15 Inline 6 cylinder, 4 stroke diesel
  • Air Inlet
    • Air cleaner
  • Control Panels
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Cooling
    • Package mounted radiator
  • Alternator
    • A Frame standard alternator
  • Control Panel
    • EMCP 4 Genset controller
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
  • Fuel
    • Fuel priming pump
    • Primary fuel filter with integral water separator
    • Secondary fuel filters
  • Exhaust
    • Exhaust flange outlet
  • Electrical Options
    • 3 Pole Circuit breaker
    • Neutral earth link
    • 24 Volt battery with rack and cables
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Mounting System
    • Captive linear vibration isolators
    • Lifting provision and drag points
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Engine and alternator pre paint, Caterpillar yellow
    • Paint - Caterpillar yellow except rails and radiators gloss black
  • Power Termination
    • Busbar
  • Generator And Attachments
    • Power center, IP22
    • Optional LC Frame generator - IP23 Protection
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Integrated voltage regulator (IVR)
    • Segregated low voltage (AC/DC) wiring panel
  • Mounting
    • Rubber vibration isolators
  • Governing System
    • Cat electronic governor (ADEM A4).
  • Lube System
    • Oil drain valves
    • Oil cooler
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting/charging
    • 24 volt starting motor
    • Batteries
    • 24 Volt battery with rack and cables

Optional Equipment:

  • Exhaust
    • Industrial, residential, critical mufflers
  • Control Panel
    • Speed and Voltage adjust potentiometers
    • PLG 4G/3G/Ethernet
    • Annunciator
    • Emergency E-Stop
  • Enclosure
    • Cat GC enclosure
  • Generator
    • Oversize and premium generators
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Electrical Options
    • 4 Pole Circuit breaker
    • Auxiliary contacts
    • Padlockable circuit breaker
    • Battery charger
    • Wet battery
  • Alternator
    • Space heater
    • AVR
  • Fuel System
    • Dual wall 8 hour fuel tank
    • Single wall 8 hour fuel tank with spill containment
    • Low fuel level shutdown
    • Low and high fuel level alarms
    • Manual fuel transfer pump
    • Fuel transfer system controls
    • Dual wall fuel tank base
  • Starting/charging
    • Jacket water heater
    • Heavy duty starting system
    • Battery chargers
    • Charging alternator
    • Oversize batteries
  • Air Inlet System
    • Single stage air filter
    • Dual element air filter
  • Certifications
    • EU Certificate of Conformance (CE)
    • EAC Certification
  • Extended Service Coverage
    • 3, 4, 5 and 10 Years
  • General
    • The following options are based on regional and product configuration:
    • Single or dual wall integral fuel tanks
    • Narrow, wide or skid base
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • CSA Certification
    • EEC Declaration of Conformity
    • Integral & sub-base UL listed dual wall fuel tanks
    • UL 2200 package
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Automatic transfer switches (ATS)
    • Single or dual wall sub-base fuel tanks
  • Enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • Industrial silencer
    • 10 dBA Attenuation silencer
    • Flexible exhaust fittings
    • 6 and 8 inch elbow kit
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • Engine mounted muffler
    • Manifold and turbocharger guards
    • 6 and 8 inch flange GP
  • Generator And Attachments
    • Oversize A Frame generator
    • Permanent magnet excitation (PMG) generator
    • Oversize LC frame generator
    • Ingress protection
    • LC frame generator
    • Space heaters
    • LC frame CIP generator
    • CIP A Frame generator
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Battery disconnect switch
    • Jacket water heater

Specifications

Generator Set Specifications

Maximum Rating
600 ekW
Minimum Rating
600 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1,800 RPM
Duty Cycle
Standby

Engine Specifications

Engine Model
C15 In-line 6, 4-cycle diesel
Bore
5.4 in
Stroke
6.8 in
Displacement
928 in³
Compression Ratio
16.1:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
EUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
131 in
Width - Maximum
60.6 in
Height - Maximum
86.1 in
Dry Weight - Genset (maximum)
8,364 lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • Cat® C15 Inline 6 cylinder, 4 stroke diesel
  • Air Inlet
    • Air cleaner
  • Control Panels
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Cooling
    • Package mounted radiator
  • Alternator
    • A Frame standard alternator
  • Control Panel
    • EMCP 4 Genset controller
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
  • Fuel
    • Fuel priming pump
    • Primary fuel filter with integral water separator
    • Secondary fuel filters
  • Exhaust
    • Exhaust flange outlet
  • Electrical Options
    • 3 Pole Circuit breaker
    • Neutral earth link
    • 24 Volt battery with rack and cables
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • IP23 Protection
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Mounting System
    • Captive linear vibration isolators
    • Lifting provision and drag points
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Engine and alternator pre paint, Caterpillar yellow
    • Paint - Caterpillar yellow except rails and radiators gloss black
  • Power Termination
    • Busbar
  • Generator And Attachments
    • Power center, IP22
    • Optional LC Frame generator - IP23 Protection
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    • Integrated voltage regulator (IVR)
    • Segregated low voltage (AC/DC) wiring panel
  • Mounting
    • Rubber vibration isolators
  • Governing System
    • Cat electronic governor (ADEM A4).
  • Lube System
    • Oil drain valves
    • Oil cooler
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting/charging
    • 24 volt starting motor
    • Batteries
    • 24 Volt battery with rack and cables

Optional Equipment:

  • Exhaust
    • Industrial, residential, critical mufflers
  • Control Panel
    • Speed and Voltage adjust potentiometers
    • PLG 4G/3G/Ethernet
    • Annunciator
    • Emergency E-Stop
  • Enclosure
    • Cat GC enclosure
  • Generator
    • Oversize and premium generators
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Electrical Options
    • 4 Pole Circuit breaker
    • Auxiliary contacts
    • Padlockable circuit breaker
    • Battery charger
    • Wet battery
  • Alternator
    • Space heater
    • AVR
  • Fuel System
    • Dual wall 8 hour fuel tank
    • Single wall 8 hour fuel tank with spill containment
    • Low fuel level shutdown
    • Low and high fuel level alarms
    • Manual fuel transfer pump
    • Fuel transfer system controls
    • Dual wall fuel tank base
  • Starting/charging
    • Jacket water heater
    • Heavy duty starting system
    • Battery chargers
    • Charging alternator
    • Oversize batteries
  • Air Inlet System
    • Single stage air filter
    • Dual element air filter
  • Certifications
    • EU Certificate of Conformance (CE)
    • EAC Certification
  • Extended Service Coverage
    • 3, 4, 5 and 10 Years
  • General
    • The following options are based on regional and product configuration:
    • Single or dual wall integral fuel tanks
    • Narrow, wide or skid base
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • EU Certificate of Conformance (CE)
    • CSA Certification
    • EEC Declaration of Conformity
    • Integral & sub-base UL listed dual wall fuel tanks
    • UL 2200 package
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Automatic transfer switches (ATS)
    • Single or dual wall sub-base fuel tanks
  • Enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • Industrial silencer
    • 10 dBA Attenuation silencer
    • Flexible exhaust fittings
    • 6 and 8 inch elbow kit
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • Engine mounted muffler
    • Manifold and turbocharger guards
    • 6 and 8 inch flange GP
  • Generator And Attachments
    • Oversize A Frame generator
    • Permanent magnet excitation (PMG) generator
    • Oversize LC frame generator
    • Ingress protection
    • LC frame generator
    • Space heaters
    • LC frame CIP generator
    • CIP A Frame generator
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Battery disconnect switch
    • Jacket water heater