fbpx

DE65 GC Generator Set (50 Hz) 16823

DE65 GC Generator Set (50 Hz)
16823 DE65 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
65.0 kVA
Minimum Rating
65.0 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
65.0 kVA
Minimum Rating
65.0 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
89.7in
Width - Maximum
35.4in
Height - Maximum
52in
Dry Weight - Genset (maximum)
2273lb

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level alarm
    • Low fuel level shutdown
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Panel mounted audible alarm
    • Earth fault
    • Earth leakage
    • USB to RS485 Communications device
    • Emergency stop with key
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Coolant heater
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor

Specifications

Generator Set Specifications

Maximum Rating
65.0 kVA
Minimum Rating
65.0 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
201.4in³
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
89.7in
Width - Maximum
35.4in
Height - Maximum
52in
Dry Weight - Genset (maximum)
2273lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level alarm
    • Low fuel level shutdown
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Panel mounted audible alarm
    • Earth fault
    • Earth leakage
    • USB to RS485 Communications device
    • Emergency stop with key
    • Battery
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Coolant heater
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor