fbpx

DE88 GC Generator Set (50 Hz) 16828

DE88 GC Generator Set (50 Hz)
16828 DE88 GC Generator Set (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

CAT
Price: Request a Quote

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating
88 kVA
Minimum Rating
88 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts

Generator Set Specifications

Maximum Rating
88 kVA
Minimum Rating
88 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
89.6in
Width - Maximum
43.3in
Height - Maximum
57.7in
Dry Weight - Genset (maximum)
1245lb

Standard Equipment:

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Genset Control
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level shutdown
    • High fuel level alarm
    • Low fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Emergency stop with key
    • Earth leakage
    • Volt free contacts for common alarm
    • Battery charger
    • Earth fault
    • Panel mounted audible alarm
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF

Specifications

Generator Set Specifications

Maximum Rating
88 kVA
Minimum Rating
88 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1in
Stroke
5in
Displacement
268.5in
Compression Ratio
17.25:1
Aspiration
Turbocharged
Fuel System
Inline
Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
89.6in
Width - Maximum
43.3in
Height - Maximum
57.7in
Dry Weight - Genset (maximum)
1245lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Genset Control
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment:

  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Auxiliary Supply Voltage
    • 120V
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Single wall tank with containment
    • Low fuel level shutdown
    • High fuel level alarm
    • Low fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Emergency stop with key
    • Earth leakage
    • Volt free contacts for common alarm
    • Battery charger
    • Earth fault
    • Panel mounted audible alarm
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit Breaker
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 250A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF